Supercharge worksite productivity with Sitemetric AI.
Learn more
Mission Critical Turnstile Gen-3

Full-height construction site turnstiles built for mission-critical jobsites.

Full-height access control with battery backup and onsite badge verification, deployed by forklift and connected to the Sitemetric platform.

94.5"
Full-height barrier
15–30
People per minute, each direction
2 hrs
Battery backup
IP56
Rated for outdoor jobsite weather
The Sitemetric Mission Critical Turnstile Gen-3, a full-height turnstile with a red canopy and galvanized steel rotors on a forklift-ready diamond plate base.

Sitemetric is trusted by 90% of the top 20 ENR companies

Proven at scale

Built for mission-critical gates.

8,700+
Workers verified on one data center campus in a day
How it keeps the gate working

Access control that works through jobsite disruptions.

At a busy construction site, every entry matters. The Mission Critical Turnstile Gen-3 combines physical security, backup power and offline access verification to help keep workers moving and access under control.

Built for uptime

Keep access working during power outages

Integrated battery backup keeps the gate running through power outages.

  • No action needed on site
  • IP56 weather rating and 18-gauge galvanized steel
  • Over-the-air firmware updates, with no site visit
Two Sitemetric full-height turnstiles side by side at a jobsite gate, with a worker in a high-visibility vest beside them.
Access security

Control who enters your construction site

A full-height, three-rotor barrier and anti-passback enforcement help prevent unauthorized access.

  • Fail-secure entry and fail-safe exit, configurable in the field during setup
  • UL 294:2018 Listed and CAN/ULC S319 Certified
Offline reliability

Keep verifying access even without a connection

Onsite verification lets the turnstile check badges and log entries when connectivity drops, then automatically sync records when service returns.*

  • 4G LTE with dual SIM, plus Wi-Fi
  • NFC support for card and mobile credentials

*The turnstile needs an initial connection to sync the current site access list. Without Wi-Fi or LTE it keeps running on the stored list but won't receive updates until it reconnects. While connected, the list updates regularly.

Deployment

Set it down. Plug it in. Get to work.

Construction sites are constantly evolving. Access points move, crews change and power or connectivity can be unreliable. The turnstile installs on your site in minutes, with no ladders, overhead work or technician dispatch.

A row of Sitemetric full-height turnstiles and an access control booth set on gravel at an active jobsite.
step one

Set it by forklift

The diamond plate base lifts by forklift. No crane, no concrete pad, no anchor bolts.

step two

Plug into 120V

One standard 15A circuit powers a group of up to three units. The controller and communications hub are factory-integrated, so there's no field wiring.

step three

It powers up and provisions itself

On first power-up it connects to the Sitemetric cloud and downloads your site's access list, with no technician or IT setup.

Integrated Construction Intelligence

One access point. A clearer picture of your workforce.

Every entry and exit is recorded and connected to the Sitemetric platform, bringing access control, badging, AI cameras and mass texting into one system. One partner supports the turnstile, the platform, monitoring and Access Control Officers.

Connected access control

Know who’s on site and when

Headcount, hours and reports come straight from gate activity.

  • Remote emergency unlock from the Sitemetric mobile app
A worker shows ID at a Sitemetric checkpoint booth beside a row of Mission Critical Turnstiles on a construction site.
Monitoring

Monitoring that keeps the gate running

Sitemetric's AI agents and 24/7 monitoring team help detect equipment issues and support faster resolution, all within one integrated system.

Badging

One badge. Connected access across your site

The turnstile reads the same Sitemetric badge workers carry across your jobsites, whether or not a given gate has a turnstile.

Specifications

Mission Critical Turnstile Gen-3 specs

UL 294:2018 Listed, CAN/ULC S319 Certified, FCC Part 15 Compliant, manufactured in the USA, with a 12-month warranty.

Technical overviewValue
Height (with base)94.5" (2,400 mm)
Width60" (1,524 mm)
Depth54" (1,372 mm)
Passage width25-15/32" (646 mm)
Throughput15 to 30 persons per minute, per direction
WeightAbout 1,400 lbs assembled
Construction18-gauge galvanized steel
Noise levelUnder 55 dB
FinishRed powder coat, Sitemetric branded
Controller locationBehind the gate, at ground level
Power and connectivityValue
Input voltage120 VAC, 50/60 Hz
CircuitOne 15A circuit per group of up to 3 units
Operating power60W mechanism, under 150W total system
Standby powerUnder 15W
Battery backupUp to 2 hours or 2,000 rotations
Cellular4G LTE Cat 6, dual SIM
Wi-Fi802.11ac (Wi-Fi 5)
NFCISO 14443 / ISO 18092
Connecting units
First unit plugs into a standard outlet; the next plugs into its power link, up to 3 units per circuit

Our guide to construction turnstiles and badge readers covers lane planning, power, connectivity and what to specify for your jobsite.

Construction site turnstile FAQs

Answers to common questions about power, connectivity, installation and certifications.

Integrated battery backup keeps the turnstile locked and monitored for up to two hours or 2,000 rotations, with automatic switchover. Entry is fail-secure and exit is fail-safe, both configurable in the field during setup.

Yes. Badges are verified at the turnstile itself, not in the cloud, so it keeps checking credentials and logging entries through a connectivity drop, then syncs records when service returns. It needs an initial connection to sync the current site access list. Offline, it runs on the stored list and receives updates once it reconnects. It connects over 4G LTE with dual SIM, plus Wi-Fi, so it doesn't depend on site IT infrastructure.

The turnstile arrives on a forklift-ready diamond plate base with the controller and communications hub factory-integrated, so there's no field wiring, anchor bolts or concrete pad. It runs on 120V, with one 15A circuit for a group of up to three units, and downloads your site's access list on first power-up.

Yes. Forklift pockets in the diamond plate base let the turnstile move as gate layouts change from excavation to fit-out, with no electrician and no permanent infrastructure to remove.

Each turnstile is rated for 15 to 30 people per minute in each direction. The number of lanes a site needs depends on peak crew size. Read the turnstile and badge reader guide for how to plan lanes.

A full-height turnstile is not an accessible route, so projects using them generally need an alternate accessible entry alongside. Ideally it reads the same credential and records the same access event, so the entry record stays complete.

It's UL 294:2018 Listed, CAN/ULC S319 Certified and FCC Part 15 Compliant, and manufactured in the USA.

Keep your jobsite moving. Keep access under control.

See how the Mission Critical Turnstile Gen-3 can support secure, reliable access throughout your project.